CC-LINK
Home > Products > Horizontal I/O> CC-LINK > UH-CL-D16C16P
Product search
Product Catalog


Digital input/output hybrid parameters | |||||
Type | UH-CL-D16C16P | ||||
Input parameter | |||||
Number of channels | 16 | ||||
Signal type | NPN & PNP | ||||
"ON" signal voltage (PNP) | 15V - 30V | ||||
"OFF" signal voltage (PNP) | -3V - 3V | ||||
"ON" signal voltage (NPN) | -3V - 3V | ||||
"OFF" signal voltage (NPN) | 15V - 30V | ||||
Connection type | 1 - Wire system | ||||
Reverse circuit protection | Yes | ||||
Isolation mode | Optical isolation from the field layer | ||||
Error diagnosis | Yes | ||||
Typical input current | 3mA | ||||
The maximum crimp area of the wire | 1.5mm² | ||||
Maximum crimp area of conductor (AWG) | AWG16 | ||||
The minimum crimp area of the wire | 0.34mm² | ||||
Minimum crimp area of conductor (AWG) | AWG22 | ||||
Strip length | 8-10mm | ||||
Output parameter | |||||
Number of channels | 16 | ||||
Signal type | PNP | ||||
"ON" signal voltage | DC 24V (±25%) | ||||
"OFF" signal voltage | DC 0V (±3%) | ||||
Connection type | 1 - Wire system | ||||
Reverse circuit protection | Yes | ||||
Isolation mode | Optical isolation from the field layer | ||||
Error diagnosis | Yes | ||||
The maximum crimp area of the wire | 1.5mm² | ||||
Maximum crimp area of conductor (AWG) | AWG16 | ||||
The minimum crimp area of the wire | 0.34mm² | ||||
Minimum crimp area of conductor (AWG) | AWG22 | ||||
Strip length | 8-10mm | ||||
Communication parameter | |||||
Communication protocol | CC-LINK | ||||
Transmission rate | Five speed can be set: 10 Mbps / 5 Mbps / 2.5 Mbps / 625 kbps / 156 kbps | ||||
Communication distance | 10 Mbps | 5 Mbps | 2.5 Mbps | 625 kbps | 156 kbps |
≤100 m | ≤160 m | ≤400 m | ≤900 m | ≤1200 m | |
Station type | Remote I/O station | ||||
Occupied work station | 1 station | ||||
Topological structure | Bus topology | ||||
Isolation mode | Electrical isolation from field floor | ||||
Transmission medium | CC-Link Special Cable (three-core shielded stranded cable) | ||||
Power supply parameter | |||||
Connection mode | PUSH-IN terminal | ||||
Operating voltage | 24V DC +20%/-15% | ||||
System feed current | <150mA | ||||
The maximum crimp area of the wire | 1.5mm² | ||||
Maximum crimp area of conductor (AWG) | AWG16 | ||||
The minimum crimp area of the wire | 0.34mm² | ||||
Minimum crimp area of conductor (AWG) | AWG22 | ||||
Strip length | 8-10mm | ||||
Basic parameter | |||||
Class of protection | IP20 | ||||
Overall dimension(H x W x D) | 43.7 mm X 100 mm X 100 mm | ||||
Operating temperature | -10 ~ 55°C | ||||
Storage temperature | -20 ~ 85°C | ||||
Relative humidity | 5 ~ 95% RH (non-condensing) | ||||
Authentication | CE | ||||
Altitude | Below 2000 meters( 80kPa) | ||||
Pollution level | Level 2 | ||||
Immunity to interference | Power cord 2kV(IEC 61000-4-4) | ||||
Overvoltage class | II | ||||
EMC anti-interference level | Zone B,IEC61131-2 | ||||
Vibration resistance | IEC 60068-2-6 | ||||
5Hz ~ 8.4Hz, amplitude 3.5mm, 8.4Hz ~ 150Hz, acceleration 9.8m /s², X, Y, Z | |||||
100 minutes in each direction (10 times, 10 minutes each, 100 minutes in total) | |||||
Impact resistance | IEC 60068-2-27, 9.8m/s², 11ms, X/Y/Z, 3 times each in 3 axes and 6 directions | ||||
LED status | |||||
PWR | On: The power supply to the module is normal | ||||
Off: The power supply to the module is abnormal | |||||
RUN | On: The system is running properly | ||||
Off: The system is not running properly | |||||
PORT1 | Blinking: Data is available on the network | ||||
PORT2 | Blinking: Data is available on the network | ||||
Channel light | On: The signal of the corresponding channel is valid | ||||
Off: The signal of the corresponding channel is invalid | |||||
Ps | On: The power supply to the system is normal | ||||
Off: The system power supply is abnormal | |||||
Pf | On: The onsite power supply is normal | ||||
Off: The onsite power supply is abnormal |