US-EC-D16XN
Supports standard EtherCAT communication protocol
Input/output configurable, up to 16 channels, NPN
Input/output configurable, up to 16 channels, NPN
Digital input/output configuration type parameter | ||
Model number | US-EC-D16XN | |
Input parameter | ||
Number of channels | The input and output can be configured for a maximum of 16 channels | |
Signal type | NPN | |
"ON" signal voltage | -3V - 3V | |
"OFF" signal voltage | 15V - 30V | |
Channel light | Green | |
Isolation mode | Optical isolation from the field layer | |
Error diagnosis | Yes | |
Typical input current | 3mA(Typical value at 24V) | |
Input interface | M12-A,5Pin,Hole end | |
Total sensor power supply | Max:2A(from UA) | |
Output parameter | ||
Number of channels | The input and output can be configured for a maximum of 16 channels | |
Signal type | NPN | |
"ON" signal voltage | DC 0V (±3%) | |
"OFF" signal voltage | DC 24V (±25%) | |
Channel light | Green | |
Reverse circuit protection | Yes | |
Load type | Resistive load, inductive load | |
Isolation mode | Optical isolation from the field layer | |
Single channel rated current | Max:500 mA(from UA) | |
Port protection | Overcurrent protection | |
Output interface | M12-A,5Pin,Hole end | |
Total output current | Max:8 A(from UA) | |
Communication parameter | ||
Communication protocol | EtherCAT | |
Transmission rate | 10/100Mbps full duplex | |
Communication distance | ≤100 m (station distance) | |
Station type | Remote I/O station | |
Occupied work station | 1 station | |
Address setting | EtherCAT specification | |
Topological structure | Bus topology | |
Isolation mode | Electrical isolation from field floor | |
Transmission medium | 2×M12,4Pin,D-code | |
Alarm function | Diagnostic alarm, process alarm | |
Power supply parameter | ||
Connection mode | 2×M12,5Pin,L-code | |
US Rated power voltage | 24V DC (18V DC ~ 36V DC) | |
US Maximum current of the power supply | Maximum input 16A, maximum output 16A (I/O port external disabled + 24V power disabled) | |
US Reverse polarity protection | Support | |
UA Rated power voltage | 24V DC (18V DC ~ 36V DC) | |
UA Maximum current of the power supply | Maximum input 16A, maximum output 16A (DO disabled) | |
UA Reverse polarity protection | Support | |
Electrical isolation between GNDS and GNDA | Yes | |
Basic parameter | ||
Class of protection | IP67 | |
Overall dimension | 225×62×35.1mm | |
Operating temperature | -25 ~ 70℃ | |
Storage temperature | -40 ~ 85°C | |
Relative humidity | 95% (non-condensing) | |
Authentication | CE | |
Altitude/pressure | 0~2000 m (80kPa) | |
Pollution level | Level 2 | |
Immunity to interference | Power cable 2kV (IEC 61000-4-4) | |
Overvoltage class | II | |
LED status | ||
Network indicator LINK | On: The network connection is successful | |
Off: The network connection fails | ||
Network indicator ACT | Blinking: Data is being transmitted | |
Off: No data is being transmitted | ||
US System power indicator | On: The power supply is normal | |
Off: The product is powered off or the power supply is abnormal | ||
UA Load power indicator | On: The power supply is normal | |
Off: The product is powered off or the power supply is abnormal | ||
RUN | On: The system is running properly | |
Blinking: The device is in the Pre-OP or Safe-OP state | ||
Off: The device is in Init or powered off state | ||
ERR | On: The system is not running properly | |
Blinking: The device is offline or the configuration of the slave station is incorrect | ||
Off: The system is running properly or is powered off | ||
Channel light | On: The signal of the corresponding channel is valid | |
Off: The signal of the corresponding channel is invalid |